3 controlling the y-axis, Controlling the y-axis -4 – Yokogawa Data Logging Software GA10 User Manual

Page 66

Advertising
background image

4-4

IM 04L65B01-01EN

Chapter 4 Monitoring Data Collection

• Y-axis Display Zone

You can switch the Y-axis display zone.

section 4.2.3

• Waveform Line Thickness

You can change the waveform line thickness. This

applies to all waveforms.

• Grid Density

You can change the grid density.

• Waveform Display Limit

With limit

Without limit

When you click the icon to select it, waveform display

limit is enabled. When you apply the waveform display

limit, the Y-axis display range is limited to the minimum

and maximum values that you specified using Scale

in Display Group. Measured values that are less than

the minimum scale value are set to the minimum

value, and values that are greater than the maximum

scale value are set to the maximum value. When you

click the icon to unselect it, waveform display limit is

disabled. In this condition, measured values outside the

scale are displayed as they are.

4.2.3 Controlling the Y-axis

• Y-axis Display Zone

You can select the Y-axis display zone.

Y-axis display zone specifies the scale position and

length. It is the waveform position and range.

Full zone

Slide zone

Auto zone

Free zone

• Full Zone: Displays all waveforms in the maximum

range

• Slide Zone: Displays each waveform cascaded from

the top to the bottom of the waveform display area

• Auto Zone: Divides the waveform display area

into equally spaced zones in accordance with the

number of waveforms and displays the waveforms

• Free Zone: Displays waveforms in user-specified

zones

• Operations in Free Zone

In Free Zone mode, you can change the Y-axis display

zone as you like.

Zoom in/out on the Y-axis

When you move the pointer near the lower or upper

edge of the Y-axis scale, the pointer changes to . In

this condition, drag the pointer to move the desired

position to zoom in or out on the Y-axis.

Moving the Y-axis

When you move the pointer on an Y-axis scale, the

pointer changes to . In this condition, drag the pointer

to move the desired position to move the Y-axis to the

desired position.

• Compact Mode and Detail Mode

A Y-axis can be displayed in compact or detail mode. In

compact mode, scale values are hidden, narrowing the

width of the Y-axis.

In detail mode, if you move the pointer on the Y-axis

and click the

icon at the top of the Y-axis, the

mode changes to compact. In compact mode, if you
click the

icon, the mode changes to detail.

• Scrolling a Y-axis Scale

When you move the pointer on an Y-axis scale, the

pointer changes to

or .

Spinning the mouse wheel in this condition causes

the Y-axis scale to scroll, maintaining the difference

between the upper and lower limits of the scale.

Click the scale initialization icon

to return the scale

to its original position.

• Zooming in or out on an Y-axis Scale

When you move the pointer on an Y-axis scale, the

pointer changes to

or . Clicking when the pointer

is

shows a scale zoom in/zoom out icon .

Click an arrow of the icon or spin the mouse wheel to

zoom in or out on the scale value in reference to the

icon position.

Click the scale initialization icon

to return the scale

to its original position.

• Changing the Active Waveform

“Waveform Display”