Q9

The device data and the data collected and recorded by the software

are not synchronized. Why?

A9

Data collected using Device time is recorded as-is by the software. In this situation, the

device data and the collected and recorded data are synchronized.

However, data collected using PC time are timestamped with the PC time and the values are

adjusted accordingly. In this situation, the device data and the collected and recorded data

based on PC time may not be synchronized.

Q10

Can the recorded data be printed?

A10

Data files can be printed using Universal Viewer. Universal Viewer is supplied with this

software and installed along with this software.

Q11

Device settings were changed. At what point are the changes applied

to data collection?

A11

Changes to devices before data collection is started

This software retrieves device information when the device is registered to the Device List. If

this information is different from the actual device information at the start of data collection,

the software will collect data but will handle it as invalid data.

Check the following settings and match them.

Channel data type, unit, span, decimal place, alarm type, and alarm value

You can use

Update Setting on the Device List to update the settings.

Changes to devices during data collection and recording

If you change the device settings during data collection and recording, the changes will not

be reflected to the software. Stop the data collection, apply the setting changes using either

of the methods below, and restart the data collection.

• Execute Update Setting of the devices in the devices List.

• Register the device again.

However, if data is being collected using Device time and you change the device’s

acquisition interval, the software will reset the entire monitor data, restart monitoring, and

stop recording.

Do not change the time on the device after starting data collection and recording, because

doing so will cause adverse effects on the monitor screen and recorded data.

Q12

What is the difference between setting the Data time to PC time and

setting the Data time to Device time?

A12

For information on the different data collection conditions, see also

“Setting Data

Collection Conditions” on page 3-18

.

The following table summarizes the major differences. For a detailed explanation, see the

following pages.

Differences

Mode

Description

Backfill

Collection and

Record Interval

Display

Saved Data Files

Trend Monitor Alarm Overview

PC time

Time on the

server PC

No

Select from

available

options

No display limitations because all

the data can be displayed on the

same time axis.

Data can be

saved to a single

file.

Device time

Time on the

device

Yes

(fills

dropped

data using

data on the

device)

The interval on

each device is

used, so it is

not possible to

specify a single

interval.

If there are

multiple devices

with different

times or scan

intervals,

Monitor Sets

are subdivided

to display each

combination of

device and scan

interval..

The page is

subdivided and

a list is displayed

for each device.

Files are divided

by a combination

of device and

scan interval.

Chapter 7 Troubleshooting

Advertising