Stuart Turner Monsoon Extra S3.0 bar Single User Manual

Page 10

Advertising
background image

- 10 -

Certain installations may require additional earthing arrangements such as equipotential

bonding. Reference should be made to the relevant regulations concerning this subject to
ensure compliance.

Wiring Of Connection Unit

WARNING: This appliance must be earthed.

The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow: Earth

Blue: Neutral Brown: Live

As the colours of the wires in the mains lead of this appliance may not correspond with

the coloured markings identifying the terminals in your connection unit proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal in the

connection unit which is marked with the letter E or by the earth symbol:

or coloured

green or green and yellow.

The wire which is coloured blue must be connected to the terminal which is marked with

the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal which is marked

with the letter L or coloured red.

The motor fitted to this pump is suitable for a 230/1/50Hz supply. It is thermally protected

by an integral auto resetting thermotrip for your safety and rated for the duty listed in the
technical specification section.

Electrical Connection

The motor is provided with a factory fitted supply cord. This must be permanently

connected to the fixed wiring of the mains supply. Means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.

A suitable method of connection would be via a double pole switched, fused connection

unit complying with BS 1363-4, protected with a fuse (see fuse section).

The connection unit should be mounted in an easily accessible position and should be

labelled if confusion is possible, to allow easy identification of the pump isolating switch.

Earthing

This appliance must be earthed via the supply cord, which must be correctly connected

to the earth point located in the terminal box.

Copper or metallic pipework must have supplementary earth bonding where the

continuity has been broken by flexible hoses or plastic components. Adjacent suction and
delivery pipes should be fitted with earthing clamps to BS 951 and connected with earthing
wire size 4 mm2 (Fig. 13).

Fig. 13

Diagram of
earth continuity
connections

Advertising