Flow Switch Circuit Test

1. First confirm visually that the flow switch reed clamp have not been dislodged during

handling or installation. The clamp must be fully located within the flow switch

body groove as shown.

2. To carry out the following test you will need to obtain a magnet, a typical fridge

magnet is suitable.

3. Ensure the power supply is switched on.
4. Position the magnet directly in front of the reed clamp as shown. If pump does not

start, then slowly move the magnet up and down to a position that exceeds the extent

of the reed clamp. The pump should instantaneously start at some point during this

extent of movement. If this does not happen, this indicates a possible fault with the

reed switch or the P.C.B which is located within the terminal box. These should be

checked electrically. Consult Stuart Turner for further instructions.