Step 4 electrical installation, Pump connections (general), Warnings – Stuart Turner Monsoon Extra S3.0 bar Single User Manual

Page 9: The motor and wiring must not be exposed to water

Advertising
background image

- 9 -

The pump should not be screwed down, ensure anti-vibration feet and flexible

hoses are used.

STEP 4 ELECTRICAL INSTALLATION

WARNINGS:

The electrical installation must be carried out in accordance with the

current national electrical regulations and installed by a competent

person.

In the interests of electrical safety a 30 mA residual current device

(R.C.D.) should be installed in the supply circuit. This may be part of a

consumer unit or a separate unit.

The motor and wiring must not be exposed to water.

Before starting work on the electrical supply ensure power supply is

isolated.

Do not allow the supply cord to contact hot surfaces, including the

motor shell, pump body or pipework. The cord should be safely

routed and secured by cable clips.

Pump Connections (General)

Cont ...

TURNER LTD

Fig. 12

Short 22 mm copper
pipe tails to connect
between gate valve
and flexible pipe.
Ensure all burrs are
removed prior to
installation into push-
in connector. Tube
must be fully pushed
home into the flexible
push-in connector.

22 mm copper outlet
pipework (discharge).

22 mm isolating valve and
fittings (not supplied). To
allow easy pump service.

Sealing washer

Sealing washer

G1 M - G ¾ M connector

G1 M - G ¾ M
connector

Flow switch.

Priming plug.

22 mm tailend x 1 ”
male adaptor.

Sealing
washer.

28 mm isolating
valve and fittings
(not supplied).

28 mm copper
inlet pipework
(suction).

1 ” Inlet ‘Y’ type
strainer.

‘O’-Ring.

Anti-vibration mounting foot.

Filter plug (removal
of this plug enables
internal gauze filter
to be cleaned).

22 mm flexible pipes with push-in connections.

Ensure that connections are fully pushed home

into pump head and that hoses are kept as

straight as possible (do not kink or twist the hose).

In the case of horizontal feeds use a 22 mm John

Guest stem elbow (not supplied). Do not bend the hose more
than 30o as they may become damaged, transmit noise or leak.