3. Priming

The pump must be primed (filled with water) before starting. Turn on water supply,

prime and vent the pump by unscrewing the priming plug (Figs. 17, 18 & 19) slowly

until all air escapes and water emerges. Re-tighten the plug.

4. Pre-Start

Check

Always ensure the pump is in a positive head position with flooded suction. A gravity

flow of one litre/min from the highest outlet is required to operate the integral flow

switch.

5. Starting

a) Switch on power and open terminal fitting. Pump should start and stop upon

demand.

b) Open and close all outlets in turn associated with the pump, (including w/c

systems) allowing water to flow from each outlet until all air is purged. As each

outlet is opened and closed, the pump will start and stop respectively.

c) Any tap or control valve within the system when opened and closed will now turn

the pump on/off. Check system for leaks, if clear the system is now operating

correctly.

d) Carefully check pump and pipework for leaks whilst pump running and stationary

before leaving the installation unattended.

For Further Technical Support

Phone the Stuart Turner Pump Assist team on 0844 98 000 97. Our staff are trained to

help and advise you over the phone or arrange for a service engineer to call.