Pipework Connections (Hot)

When a hot water cylinder or storage tank is used, ensure the pipework size from the

cold water storage to the hot water storage is of adequate size and a minimum of 28 mm.

The pump must be supplied with a dedicated feed direct from the hot water

cylinder or storage tank.

Ensure the pipework size from the hot water storage tank to the pump is of adequate

size and a minimum of 28 mm. The supply must be air free and connection to the cylinder
can be via an Essex flange, or by one of the following methods shown in Fig. 8.

When the method of connection is to be made via the expansion pipe, the cold water

cistern should be at least 1.5 metres above the top of the hot water cylinder.

NOTE: Care should be taken in the design of pipework runs, to minimise the risk of air

locks in pipework.

Pipework Connections (Connection between pump and shower valves or taps)

This should run as far as possible in 22 mm copper tube. Any bend requirements should

be achieved by hand drawing the tube or by use of the appropriate bend fittings. Pipework
should only be reduced to 15 mm copper if necessary when entering the terminal fittings.
By this method the maximum performance of the pump will be maintained. All pipework
should be securely clipped.

STEP 3 PUMP CONNECTIONS

(Release And Connection Of Push-in Connectors)

WARNINGS: (Push-in Connectors)

Do not use stainless steel, chrome or nickel plated pipe with Stuart

Turner push-in plumbing connections.

Do not introduce solder flux into the joint or surrounding area as

connectors will be attacked and may fail.

All solder joints should be completed and flux residues removed

before final connection to push-in connections, either on flexible hose

or pump head.

Do not allow contact with oil or cellulose based paints, paint thinners

or strippers, acid based descalents or aggressive cleaning agents.

Fig. 8

Most preferred

Least
preferred

NOT RECC

NOT RECC

Existing
secondary
tappings 22 mm

Essex flange
28 mm

Surrey flange
32 mm outlet

Off expansion
pipe, off-set 45°,
28 mm pipework

Off vertical
expansion pipe,
28 mm pipework