Keywords – Boltek Lightning/2000 User Manual
Page 74
L I G H T N I N G / 2 0 0 0
74
74
74
74
addition to or instead of the normal automatic screen capture 
process). Text files may be produced, consisting of virtually 
any information, and then be sent to a server via FTP. 
Commands may be sent to a serial port to control external 
devices. Text may be written to the Custom Summary 
window, consisting of an almost unlimited variety of 
information produced by Lightning/2000. An automatically 
generated email may be sent. 
The names of the commands are not case sensitive.
Keywords
Keywords that evaluate to a per minute stroke or flash count 
can be followed by a parameter. Then the count will evaluate 
to the number of strokes or flashes in the last N minutes, 
where N is the parameter. 
The parameter "N" may be either a positive integer, or a 
positive real number. Real numbers less than 1 must start 
with a zero. 
For example, "0.1" is a valid parameter, but ".1" is not.
For example, the @CGFlashCount keyword will evaluate to 
the number of CG flashes in the last minute, but if you 
specify @CGFlashCount( 2 ), then it will evaluate to the 
number of CG flashes in the last 2 minutes. 
@CGFlashCount( 1 ) is identical to @CGFlashCount. 
There is a limit of 60 minutes for the various stroke counts. 
By default, the @Peak keywords will return the peak count 
for the day. 
Entering ( N ) (where N is a number of minutes) after the 
@Peak keyword will return the peak value in the last N 
minutes.