Brocade VDX 6740 Hardware Reference Manual

35

53_1002829_02

Chapter

5

Brocade VDX 6740 FRU Replacement Procedures

In this chapter

Before beginning the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Combined FRU replacement in a Brocade VDX 6740. . . . . . . . . . . . . . . . . . 36

Power supply replacement in a Brocade 6740T and 6740T-1G. . . . . . . . . . 39

Fan replacement in a Brocade VDX 6740T and Brocade VDX 6740T-1G . . 42

Before beginning the installation

The field-replaceable units (FRUs) in the Brocade VDX 6740 switches can be removed and replaced
without special tools. The switches can continue operating during the FRU replacements if the
conditions specified in the procedures are followed. switches.

NOTE

Read the

“Installation and safety considerations”

on page 7 before servicing.

CAUTION

This document describes how to change field-replaceable units (FRUs) for switches with either a
port-side air exhaust or a port-side air intake. You must replace a failed FRU with a FRU of the
same type. This applies to both power supplies and fan assemblies.
A new FRU must have the same part number (P/N) as the FRU being replaced. The
manufacturing P/N is located on the top of the FRU.
The P/N ends in either -F (front-to-rear airflow or exhaust) or -R (rear-to-front airflow or intake).
You must use a replacement FRU that has the same airflow designator with the part number.

DANGER

The procedures in this manual are for qualified service personnel.

If a mismatched power source or fan assembly is installed by mistake, a warning is sent to the
console. The warning messages will be similar to the following:

For a fan mismatch: [WARNING, Brocade VDX 6740, MISMATCH in FAN Air Flow direction.
Replace FRU with fan air flows in same direction.

For a power supply or combined power supply and fan mismatch: [WARNING, Brocade VDX
6740, MISMATCH in PSU-FAN FRUS Air Flow direction. Replace PSU with fan air flows in same
direction.

Advertising