Environmental requirements, Data transmission ranges, Table 16 – Brocade VDX 6740 Hardware Reference Manual (Supporting VDX 6740, VDX 6740T, and VDX 6740T-1G) User Manual

Page 60

Advertising
background image

48

Brocade VDX 6740 Hardware Reference Manual

53_1002829_02

Environmental requirements

A

Environmental requirements

Table 15

lists the acceptable environmental ranges for both operating and nonoperating (such as

during transportation or storage) conditions.

Data transmission ranges

Table 16

provides the data transmission ranges for different cable types and port speeds for all

ports.

TABLE 16

Data transmission ranges

TABLE 15

Environmental requirements

Condition

Acceptable during operation

Acceptable during non-operation

Ambient
Temperature

0º to 40ºC (32º to 104ºF)

-25º to 70ºC (-13º to 158ºF)

Humidity

10% to 85% RH non-condensing, at
40ºC (104ºF)

10% to 90% RH non-condensing, at 70ºC
(158ºF)

Altitude

0 to 3 km (9,842 feet) above sea level

0 to 12 km (39,370 feet) above sea level

Shock

20 G, 6 ms, half-sine wave

33 G, 11 ms, half-sine wave, 3/eg Axis

Vibration

0.5 G sine, 0.4 gms random, 5-500 Hz

2.0 G sine, 1.1 gms random, 5-500 Hz

Airflow

Brocade VDX 6740 (port side intake)

Maximum - 43.7 cmh (25.7 cfm)
Nominal - 19.5 cmh (11.5 cfm)

Brocade VDX 6740T

Maximum - 83.8 cmh (49.3 cfm)
Nominal - 44.7 cmh (26.3 cfm)

N/A

Cable and connector type

Connector

Cable

Distance

Active copper
direct-attach

SFP+ copper

Twinaxial

Up to 20 m (65.62 ft)
[1 m (3.28 ft), 3 m (9.84 ft), and
5 m (16.40 ft) supported]

Active optical cable
direct-attach (Laserwire)

SFP+ copper

Plastic optical fiber

Up to 30 m (98.43 ft)

10GE-SR SFP+

SFP+ MMF,
SR

MM OM2
MM OM3

82 m (269.03 ft)
300 m (984.25 ft)

10GE-LR SFP+

SFP+ SMF, LR SM

10 km (6.2 miles)

Advertising