Sysmon port port-crc-test log-backoff – Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual
Page 157
Multi-Service IronWare Administration Guide
139
53-1003028-02
sysmon port port-crc-test log-backoff
5
sysmon port port-crc-test log-backoff
Disables syslog messages for a specified number of events, before they are logged again for the
port CRC error monitoring test.
Syntax
sysmon port port-crc-test log-backoff num
Command
Default
Parameters
num
Specifies the number of events to skip before logging syslog messages again.
The range of values is 1 through 14,400.
Command
Modes
Global configuration mode.
Usage
Guidelines
Examples
The following example disables syslog for 1,000 events.
Brocade(config)# sysmon port port-crc-test log-backoff 1000
History
Related
Commands
sysmon port port-crc-test
Release
Command History
Multi-Service IronWare R05.5.00 This command was introduced