Multi-Service IronWare Administration Guide

221

53-1003028-02

CFM monitoring for ISID

6

CFM monitoring for ISID

•

ISID is configured in edge devices (BEB) of a PBB network.

•

CFM is configured for ISID in a BEB and is monitored between BEBs.

•

The CCM interval for the sub-second timer is supported for CER with PBIF version 0x56 and
greater.

•

Loopback, Link trace, and delay measurement messages are supported for ISID.

•

MIP functionality is not applicable for ISID.

Configuring CFM monitoring for ISID

The following PBB configuration is mandatory to configure CFM ISID.

1. Configure ESI for B-VLAN and VLAN under the ESI.

2. Add ports into the configured B-VLAN.

3. Configure ESI for ISID and ISID under the ESI.

4. Associate ISID ESI as client ESI with B-VLAN ESI.

Use the following commands for each step in the CFM configuration for ISID.

1. Domain configuration.

Brocade(config-cfm)# domain-name ISID_domain level 7

Syntax: [no] domain-name name level value

2. MA configuration.

Brocade(config-cfm-md-ISID_domain)# ma-name ISID_2000 esi isid_1 isid 2000

priority 7

Syntax: [no] ma-name name esi esiname isid isidvalue priority value

3. MEP configuration.

Brocade(config-cfm-md-ISID_domain-ma-ISID_2000)# mep 1 down port eth 1/1

Syntax: [no] mep id dir port portId

Sample configuration

Brocade_BEB_1(config)#interface eth 1/1

Brocade_BEB_1(config-if-e1000-1/1)#enable

Brocade_BEB_1(config-if-e1000-1/1)#port-type backbone-network

Brocade_BEB_1(config)#esi isid_1 encapsulation isid

Brocade_BEB_1(config-esi-isid_esi_1)#isid 2000

Brocade_BEB_1(config)# esi bvlan_1 encapsulation bvlan

Brocade_BEB_1(config-esi-bvlan_1)#vlan 200

Brocade_BEB_1(config-esi-bvlan_1-vlan-200)#tagged eth1/1

Brocade_BEB_1(config-esi-bvlan_1)#esi-client isid_1