Np memory errors, Appendix f, Appendix f, “np memory errors – Brocade Multi-Service IronWare Administration Guide (Supporting R05.6.00) User Manual
Page 415: Appendix

Multi-Service IronWare Administration Guide
397
53-1003028-02
Appendix
F
NP Memory Errors
The Sysmon NP Memory Error Monitoring event monitors memory errors on interface modules. This
appendix lists the interface cards that support NP memory error monitoring. It also details the
different NP memory errors supported on each interface card.
The following interface cards support NP memory error monitoring:
•
BR-MLX-40Gx4-X
•
BR-MLX-10Gx24
•
BR-MLX-100Gx2-X(100G)
•
Gen-1
•
NI-XMR-10Gx4
•
NI-MLX-10Gx4)
•
Gen-1.1
•
BR-MLX-1GCx24-X
•
BR-MLX-1GFx24-X
•
BR-MLX-10Gx4-X
•
Gen-2
•
NI-MLX-10Gx8-M
•
NI-MLX-10Gx8-D
•
BR-MLX-10Gx8-X
TABLE 94
NP memory errors supported on BR-MLX-40Gx4-X interface cards
External Memory Errors
1
PRAM Parity Errors
2
CAM2PRAM Parity Errors
3
LBLRAM Parity Errors
4
CAM wd10 Parity Error
5
CAM GIO Parity Error
6
CAM PEO Parity Error
7
CAM Operation Parity Error
8
CAM Result Bus Parity Error
Internal Memory Errors
1
Tx Deframer MVLAN Flag FIFO Parity
2
Tx Deframer MVLAN control Packet FIFO Parity
3
Tx Deframer MVLAN replication table Parity
4
Tx Deframer MVLAN start offset FIFO Parity