Brocade TurboIron 24X Series Configuration Guide User Manual
Page 1095

Brocade TurboIron 24X Series Configuration Guide
1061
53-1003053-01
Syslog messages
Notification
Authentication Enabled on <portnum>
The multi-device port authentication feature
was enabled on the on the specified
<portnum>.
Notification
BGP Peer <ip-addr> DOWN (IDLE)
Indicates that a BGP4 neighbor has gone
down.
The <ip-addr> is the IP address of the
neighbor BGP4 interface with the device.
Notification
BGP Peer <ip-addr> UP (ESTABLISHED)
Indicates that a BGP4 neighbor has come
up.
The <ip-addr> is the IP address of the
neighbor BGP4 interface with the Brocade
device.
Notification
DOT1X issues software but not physical port
down indication of Port <portnum> to other
software applications
The device has indicated that the specified
is no longer authorized, but the actual port
may still be active.
Notification
DOT1X issues software but not physical port
up indication of Port <portnum> to other
software applications
The device has indicated that the specified
port has been authenticated, but the actual
port may not be active.
Notification
DOT1X: Port <port_id> Mac <mac_address>
-user <user_id> - RADIUS timeout for
authentication
The RADIUS session has timed out for this
802.1x port.
Notification
ISIS ENTERED INTO OVERLOAD STATE
The Layer 3 Switch has set the overload bit
to on (1), indicating that the Layer 3 Switch
IS-IS resources are overloaded.
Notification
ISIS EXITING FROM OVERLOAD STATE
The Layer 3 Switch has set the overload bit
to off (0), indicating that the Layer 3 Switch
IS-IS resources are no longer overloaded.
Notification
ISIS L1 ADJACENCY DOWN <system-id> on
circuit <circuit-id>
The Layer 3 Switch adjacency with this
Level-1 IS has gone down.
The <system-id> is the system ID of the IS.
The <circuit-id> is the ID of the circuit over
which the adjacency was established.
Notification
ISIS L1 ADJACENCY UP <system-id> on
circuit <circuit-id>
The Layer 3 Switch adjacency with this
Level-1 IS has come up.
The <system-id> is the system ID of the IS.
The <circuit-id> is the ID of the circuit over
which the adjacency was established.
Notification
ISIS L2 ADJACENCY DOWN <system-id> on
circuit <circuit-id>
The Layer 3 Switch adjacency with this
Level-2 IS has gone down.
The <system-id> is the system ID of the IS.
The <circuit-id> is the ID of the circuit over
which the adjacency was established.
Notification
ISIS L2 ADJACENCY UP <system-id> on
circuit <circuit-id>
The Layer 3 Switch adjacency with this
Level-2 IS has come up.
The <system-id> is the system ID of the IS.
The <circuit-id> is the ID of the circuit over
which the adjacency was established.
TABLE 176
Brocade Syslog messages (Continued)
Message level
Message
Explanation