Disabling snmp traps – Brocade TurboIron 24X Series Configuration Guide User Manual
Page 59

Brocade TurboIron 24X Series Configuration Guide
25
53-1003053-01
Configuring basic system parameters
TurboIron(config)#snmp-server enable traps holddown-time 30
The command in this example changes the holddown time for SNMP traps to 30 seconds. The
device waits 30 seconds to allow convergence in STP and OSPF before sending traps to the SNMP
trap receiver.
Syntax: [no] snmp-server enable traps holddown-time <secs>
The <secs> parameter specifies the number of seconds and can be from 1 – 600 (ten minutes).
The default is 60 seconds.
Disabling SNMP traps
TurboIron X Series devices come with SNMP trap generation enabled by default for all traps. You
can selectively disable one or more of the following traps.
NOTE
By default, all SNMP traps are enabled at system startup.
Layer 2 traps
The following traps are generated on devices running Layer 2 software:
•
SNMP authentication keys
•
Power supply failure
•
Fan failure
•
Cold start
•
Link up
•
Link down
•
Bridge new root
•
Bridge topology change
•
Locked address violation
Layer 3 traps
The following traps are generated on devices running Layer 3 software:
•
SNMP authentication key
•
Power supply failure
•
Fan failure
•
Cold start
•
Link up
•
Link down
•
Bridge new root
•
Bridge topology change
•
Locked address violation
•
BGP4
•
OSPF
•
VRRP