5.6.5 Manaras

Operator

























5.6.5.1 Installation

of Manaras Operator

The Manaras Operator has two sets of mounting holes: outside the frame for wall mounting and inside the
frame for hood mounting. To open the control box cover, loosen the screw at the base of the cover. If the
cover cannot be fully opened, the retaining cam may be used to hold the cover in other positions. See the
following Figure, Control Box Cover Opening
















IMPORTANT NOTES: 1. This Operator Must Be Installed A Minimum Of 8 ft. (2.4m) Above Floor.

2. Remove the Safety Bracket only on the side of the door where the

motor is to be installed. Retain bracket and hardware for later use.

3. Verify that framing is structurally sound for mounting motor.