Operation of door, Manaras terminal input connections, Remove temporary velcro strips – Hired-Hand RS-400 Door User Manual
Page 21

Part No. 4801-5170 Rev 5/08
RS 400 Door
Page 21 of 26
Top of Track Assembly
Remove
Velcro
Strips
Front
Track
Velcro
Center
Curtain
Back
Track
Velcro
Back
Curtain
Velcro
Front
Curtain
Velcro
5.6.5.9
Wiring Options to the Manaras Operator Terminal Block
•
Radio Controls: Consists of a radio receiver unit
and remote transmitters. These controls consist of
an RF signal being emitted on a "pulse" basis to a
mated receiver tuned to the same "pulse" rate. Once
the receiver accepts the code, a relay is activated
closing a set of contacts.
•
Photo-electric units: Can be used as opening and
reversing devices. An infra red light is emitted from
the control to a reflector and back. If, during closing
travel of the door, the light beam is broken, the door
will reverse to the fully open position.
•
Digital Keypad: Consists of a control head which
is pedestal mounted. Similar to a telephone touch
pad it allows the selective coding of a four number
series. Once the programmed series of numbers is
received in their set order, a relay closes and
completes a circuit.
•
Card Reader: A magnetic-mechanical device
which accepts sealed and coded cards. The cards
trigger magnets to raise in the cartridge head,
releasing a lock mechanism which allows a deeper
insertion of the card. The card then contacts a
switch that closes the circuit.
•
Key Switch: Momentary contact will open door.
Can be wall or post mounted for interior or exterior
use.
* Refer to the Figure, Manaras Terminal Input
Connections.
6.
Operation of Door
Before normal door operation can begin, door
must be tested to ensure door is installed and
functioning correctly. To test the door, open and
close the door (See Sections 6.1, 6.2 and 6.3) a
few times to test door operation and remove any
wrinkles in the door curtain. Test all options you
have installed on door. If you detect any
problems, STOP. Disconnect electrical power, if
applicable. Contact your distributor for
assistance.
After door testing is complete, remove two 18"
Velcro strips (1 Front, 1 Back) from top of each
Left and Right Track Assembly. See diagram at
right.
NOTE:
Certain accessory devices may require additional power wiring.
1
L
N
9
8
7
6
5
4
3
2
Line
Neutral
THREE PUSH BUTTON
OPEN
CLOSE
STOP
RADIO RECEIVER
PUSH BUTTON
(OPEN/CLOSE COMMAND)
PHOTO CELL
EXTERNAL
INTERLOCK
DIGITAL KEYPAD
KEY STATION
(OPEN COMMAND)
CARD READER
(OPEN COMMAND)
24 VAC PILOT LIGHT
(to indicate “POWER ON”)
24 V
A
C
PO
W
E
R
ST
O
P
COM
OP
E
N
CLOS
E
SA
FET
Y
DE
VI
CE
COM
O
P
EN
/
CLOS
E
24 V
A
C
Ground
PUSH-BUTTON STATION
Manaras Terminal Input Connections
18"(45.7cm)
Remove Temporary Velcro Strips