Part No. 4801-5170 Rev 5/08
RS 400 Door
Page 7 of 26
18"
45.7 cm
5.1 Operator
Power
options
• Manual Chain Hoist……………………... Power not required.
See Section 5.6.4 for installation instructions.
• Manaras Operator Ratings:
115 VAC
208 VAC
230 VAC
460 VAC-3ph
@ 8.0 amp
@ 2.1 amp
@ 4.0 amp
@ 1.0 amp
See Section 5.6.5 for installation instructions.
5.2 Tools
Required
Tools Required
3/8 in. (10 mm) Power screwdriver (portable)
Socket.
3/16 in. (5 mm) Drill bit and power drill
Hammer
Carpenter's level
Tape measure
NOTE:
Other Tools May Be Required According To Installation
5.3 Overview
The RS 400 Door is shipped in three sections which must be assembled. The RS 400 comes with a Head Unit
that is preassembled in the Factory. The part number of the Head Unit varies with the width of the Door. The
Right and Left Tracks vary with the Height of the door. The Right Track and the Left Track must be attached to
the Head Unit in the field. See Diagram 2.
The Head Unit and Tracks attach to side of the building using mounting holes pre-drilled in the Head Unit and
the Tracks. The Curtain attaches to the back plate, drive pipe and top bar. Hook & Loop holds the curtain in
place and seals the curtain. The Loop is laminated to the Back Plate, Drive Pipe and the Top bar.
The Floating hook is attached to the Left Track and Right Track. The Curtain is raised and lowered by a
manual or motorized drive. The top covers are installed to each curtain system to enclose the drive pipe.
Please read and understand all instructions in this
manual before beginning assembly and installation of
your new RS 400 Door.
5.4
Adjusting the Clear Opening
Locate your particular system in Table 1, page 3. For
the door size that you are installing, read overall width
(A) and overall height (B) of the door. If necessary,
adjust the dimensions of the mounting posts or
framing members to the height and width of your
particular RS 400-door system as shown in Diagram 2.
Refer to Section 5.5 for details of door attachment to
framing members. Framing material must be of
sufficient strength for securing screws.
Make sure that mounting posts or framing members
are positioned accurately so that the flanges of the
vertical members align with the mounting posts or
framing members.
4 1/4"
10.8
Diagram 2
Clear Opening
Curtain material
Height
Width
B
See Table 1
A
See Table 1