Part No. 4801-5170 Rev 5/08

RS 400 Door

Page 7 of 26

18"

45.7 cm

5.1 Operator

Power

options

Manual Chain Hoist……………………... Power not required.

See Section 5.6.4 for installation instructions.

Manaras Operator Ratings:

115 VAC

208 VAC

230 VAC

460 VAC-3ph

@ 8.0 amp

@ 2.1 amp

@ 4.0 amp

@ 1.0 amp

See Section 5.6.5 for installation instructions.

5.2 Tools

Required

Tools Required

3/8 in. (10 mm) Power screwdriver (portable)

Socket.

3/16 in. (5 mm) Drill bit and power drill

Hammer

Carpenter's level

Tape measure

NOTE:

Other Tools May Be Required According To Installation

5.3 Overview

The RS 400 Door is shipped in three sections which must be assembled. The RS 400 comes with a Head Unit
that is preassembled in the Factory. The part number of the Head Unit varies with the width of the Door. The
Right and Left Tracks vary with the Height of the door. The Right Track and the Left Track must be attached to
the Head Unit in the field. See Diagram 2.

The Head Unit and Tracks attach to side of the building using mounting holes pre-drilled in the Head Unit and
the Tracks. The Curtain attaches to the back plate, drive pipe and top bar. Hook & Loop holds the curtain in
place and seals the curtain. The Loop is laminated to the Back Plate, Drive Pipe and the Top bar.

The Floating hook is attached to the Left Track and Right Track. The Curtain is raised and lowered by a
manual or motorized drive. The top covers are installed to each curtain system to enclose the drive pipe.

Please read and understand all instructions in this
manual before beginning assembly and installation of
your new RS 400 Door.

5.4

Adjusting the Clear Opening

Locate your particular system in Table 1, page 3. For
the door size that you are installing, read overall width
(A) and overall height (B) of the door. If necessary,
adjust the dimensions of the mounting posts or
framing members to the height and width of your
particular RS 400-door system as shown in Diagram 2.
Refer to Section 5.5 for details of door attachment to
framing members. Framing material must be of
sufficient strength for securing screws.
Make sure that mounting posts or framing members
are positioned accurately so that the flanges of the
vertical members align with the mounting posts or
framing members.

4 1/4"

10.8

Diagram 2
Clear Opening

Curtain material

Height

Width

B

See Table 1

A

See Table 1