After installation, verify that there is no obstacle in the way when opening the control box cover. If an
obstacle exists preventing the cover from opening, it is possible to remove the cover by cutting the plastic
hinge at its thinnest point or unscrewing it from the box before putting the operator on the wall or hood.
Closing the cover will also require using two supplementary screws. See the following Figure, Hinge
Elimination And Cover Fastening By Screws.
5.6.5.2 Mounting
the
Manaras Operator
Locate the four mounting
holes. The optimum distance
between the door shaft and
operator drive shaft is
between 12" and 15". Mount
the OPERA unit by fastening
it to the wall, bench or hood
with 3/8" or 1/2" thru-bolts or
if the wall is of such
construction so as to prohibit
use of thru-bolts, lag bolts
and shields of sufficient size
may be used. Do not tighten.
See the following Figure,
Mounting Dimensions For
Wall Or Hood.
Cut the hinge
lengthwise.
Remove the two
screws
Replace two
screws to fix
the cover.
Hinge Elimination And Cover Fastening By Screws
or
Mounting Dimensions for Wall or Hood