INSTALLATION

IDEALARC® DC-600

A-4

RECONNECT PROCEDURE

Multiple voltage machines are shipped connected to
the highest input voltage listed on the machineʼs rating
plate. Before installing the machine, check that the
Reconnect Panel in the Input Box Assembly is con-
nected for the proper voltage.

Failure to follow these instructions can cause
immediate failure of components within the
machine.

When powering welder from a generator be sure
to turn off welder first, before generator is shut
down, in order to prevent damage to the welder

------------------------------

To reconnect a multiple voltage machine to a different
voltage, remove input power and change the position
of the reconnect board on the Reconnect Panel.
Follow The Input Connection Diagram located on the
inside of Case Back Input Access Door. These con-
nection diagrams for the following codes are listed
below.

1.

For Dual Voltage except 380/500-460/575, see
Figure A.4. (M15009)

2.

For 220/380/460, see Figure A.5. (M15010)

3.

For 380/500-460/575, see Figure A.6. (M15011)

4.

For 460 and 440 Single Voltage, see Figure A.7.
(S17894)

5.

For 230/460/575, see Figure A.8. (M15666)

6.

For Voltages not listed, see the Input Connection
Diagram pasted on the inside of the Case
Back Input Access Door.

L3
L2
L1

LINK

LINES
INPUT

GND

H2

H1

H3

L3
L2
L1

LINK

LINES
INPUT

H3

H1

H2

GND

W

V

U

W

V

U

CONTACTOR

CRI

CRI

CONNECTION FOR HIGHEST RATING PLATE VOLTAGE, 50 OR 60 HZ.

CONNECTION FOR LOWEST RATING PLATE VOLTAGE, 50 OR 60 HZ.

CTOR

1. TURN OFF THE INPUT POWER USING THE DISCONNECT SWITCH AT THE FUSE BOX
2. DISCONNECT AND INSULATE THE H2 LEAD TERMINAL WITH TAPE TO PROVIDE AT
LEAST 600 VOLT INSULATION.
3. CONNECT L1, L2 & L3 INPUT SUPPLY LINES H1 AND H3 TRANSFORMER LEADS TO THE INPUT SIDE OF
THE CRI CONTACTOR AS SHOWN.
4. CONNECT TERMINAL MARKED TO GROUND PER LOCAL AND NATIONAL ELECTRIC CODES.
5. MOUNT THE LINKS IN THE POSITIONS SHOWN WITH THE PROVIDED HEX NUTS,
DOUBLE UP THE LINKS IN TWO OF THE POSITIONS TO SAVE THEM FOR FUTURE USE. SECURE THE
REMAINING HEX NUTS IN PLACE.

1. TURN OFF THE INPUT POWER USING THE DISCONNECT SWITCH AT THE FUSE BOX
2. DISCONNECT AND INSULATE THE H3 LEAD TERMINAL WITH TAPE TO PROVIDE AT
LEAST 600 VOLT INSULATION.
3. CONNECT L1, L2 & L3 INPUT SUPPLY LINES H1 AND H2 TRANSFORMER LEADS TO THE INPUT SIDE OF
THE CRI CONTACTOR AS SHOWN.
4. CONNECT TERMINAL MARKED TO GROUND PER LOCAL AND NATIONAL ELECTRIC CODES.
5. MOUNT THE LINKS IN THE POSITIONS SHOWN WITH THE PROVIDED HEX NUTS.

PILOT

TRANSF.

PILOT

TRANSF.

FIGURE A.4-Reconnect Panel Board Positions for Dual Voltage Machines