TERMINAL STRIPS

Terminal strips are available behind the cover on the
case front to connect wire feeder control cables that
do not have a 14 Pin MS-type connector. These termi-
nals supply the connections as shown in the following
Terminal Strip charts. NOTE: There are two work
sense lead connection points on the terminal strip.
Connect both the work sense lead #21 from the 14 pin
connector and #21 lead of the control cable to “-21”
when welding positive polarity or to “+21” when weld-
ing negative polarity.

TERMINAL STRIP 1 (T.S.1)

TERMINAL STRIP 2 (T.S.2)

Lead No.

Function

75

Output Control

76

Output Control

77

Output Control

Lead No.

Function

+21

Work Connection (Electrode Negative)

-21

Work Connection (Electrode Positive)

2

41

42 VAC

4 Trigger

Circuit

2 Trigger

Circuit

31 115

VAC

1

32 115

VAC

1

A-8

INSTALLATION

IDEALARC® DC-600

A-8

AUXILIARY POWER AND
CONTROL CONNECTIONS

Located at the left side of the front of the welder
behind a hinged cover is a 115VAC duplex receptacle
for auxiliary power (60 Hertz Models only). On the right
side of the case front is a 14 Pin MS type receptacle
for connection of auxiliary equipment such as wire
feeders. Also, terminal strips with 115VAC and con-
nections for auxiliary equipment are located behind the
hinged access panel on the right side of the case front.
(see Auxiliary Power Table for details)

115VAC DUPLEX RECEPTACLE (60 HERTZ
MODELS ONLY)

The 115VAC duplex receptacle is protected by a circuit
breaker located on the nameplate. The receptacle is a
NEMA 5-15R.

AUXILIARY POWER TABLE

Voltage and Circuit Breaker Ratings at Auxiliary Power

Connections for Various Models

Auxiliary

60 Hz

50/60 Hz

Power

Models

Models

Connections

At Duplex

115V 15A

No Duplex

Receptacle

Terminal strip

115V 15A

115V 15A

terminals 31 & 32

MS-Receptacle

115V 15A

115V 15A

pins A & J

MS-Receptacle

42V 10A

42V 10A

pins I & K

PIN

LEAD NO.

FUNCTION

A

32

115 VAC

B

GND

Chassis Connection

C

2

Trigger Circuit

D

4

Trigger Circuit

E

77

Output Control

F

76

Output Control

G

75

Output Control

H

21

Work Sense Connection

2

I

41

42 VAC

J

31

115 VAC

1.

K

42

42 VAC

L

---

---

M

---

---

N

---

---

F = 7 6

G = 7 5

H = 2 1

I = 4 1

J = 3 1

K = 4 2

A = 3 2

B = G N D

C = 2

D = 4

E = 7 7

L

N

M

1.

115VAC circuit is on all models.

2.

As shipped from the factory Lead #21 from the 14 Pin connector is
connected to “-21” on the terminal strip (T.S.2). This is the config-
uration for positive welding. If welding negative polarity, connect
lead #21 to the “+21” connection point on the terminal strip
(T.S.2).

14 PIN MS TYPE RECEPTACLE

(For MS3106A-20-27PX Plug. L.E.C. Part #S12020-32)

Refer to the figure A.10 for the available circuits in the
14 pin receptacle.

42 VAC is available at receptacle pins I and K.
A 10 amp circuit breaker protects this circuit.

115 VAC is available at receptacle pins A and J (All
Models). A 15 amp circuit breaker protects this circuit.
Note that the 42 VAC and 115 VAC circuits are electri-
cally isolated from each other.

FIGURE A.10 FRONT VIEW OF 14-PIN
CONNECTOR RECEPTACLE