DIAGRAMS

F-7

IDEALARC® DC-600

N.C. Tape up bolted connection if lead #21 is extended.

N.D. Connect the control cable ground lead to the frame terminal

marked near the power source terminal strip. The power

source grounding terminal (marked and located near the power

source input power connections) must be properly connected to

electrical ground per the power source operating manual.

N.A. Welding cables must be of proper capacity for the current and

Above diagram shows electrode connected positive. To change polarity,

turn power off, reverse the electrode and work leads at the power

NEGATIVE

POSITIVE

32 31 2 4

GND

21

N.A.

N.D.

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

POWER SOURCE

N.E.

Only qualified persons should install, use or

service this machine.

Do not operate with covers removed.

Disconnect power source before

servicing.

Do not touch electrically live parts.

CABLE

21

FOR CONTROL CABLE

WITH 14 PIN

MS-TYPE

PLUG CONNECTOR

OR

FOR CONTROL CABLE

WITH TERMINAL STRIP

LEAD CONNECTORS

CONTROL CABLE

S22

977

source and position the switch on wire feeder (if equipped )

to proper polarity. Also refer to note N.F.

N.B. & N.C.

14-PIN

RECEPTACLE

A

B

C

N.E. If using an older LN-8 control cable: connect lead #75 to #75 on

terminal strip, connect lead #76 to #76 on terminal strip, connect

lead #77 to #77 on the terminal strip.

the #21 terminal that matches work polarity. This connection must be changed whenever the electrode polarity is changed.

N.G. If lead #21 is to be connected to the terminal strip, connect to

N.F. The LN-9 voltage control jumpers must be connected as follows

(refer to LN-9 Operating Manual):

White jumper on voltage board to pin "S" .

Blue jumper on voltage board (later units only),

or on start board (earlier units), to pin "B".

remote voltage sensing work lead may be ordered for this purpose.

N.B. Extend lead #21 from control cable with terminal strip connectors or

from 14-pin receptacle using #14 AWG or larger insulated wire

duty cycle of immediate and future applications.

Connect it directly to the work piece keeping it electrically

convenience, this extended #21 lead should be taped to the

welding work lead. (If the length of work lead circuit is

short, and connections can be expected to be reliable, then

control cable lead #21 does not need to be extended and can be

directly connected to terminal #21 on the terminal strip. Note

that this is not the preferred connection because it adds error

separate from the welding work lead circuit and connection. For

to the wire feeder voltmeter reading.)

physically suitable for the installation. An S16586-[LENGTH]

TO LN-8 OR LN-9

CONTROL

N.F.

INPUT CABLE PLUG

41

423

1

32

75

76

77

N.E.

N.G.

21

-
21

+

REMOTE VOLTAGE SENSING LEAD

10-30-98F

N.H. Illustration does not necessarily represent actual position of appropriate

output studs. Refer to power source instruction manual for more info.

N.H.

CONNECTION OF LN-8 OR LN-9 TO THE CV-655, DC-655 OR DC-600 POWER SOURCE

For proper setting of switches on power source,

see power source operating manual.