Diagrams, F-10, Idealarc® dc-600 – Lincoln Electric IM642 IDEALARC DC-600 User Manual

Page 51

Advertising
background image

F-10

DIAGRAMS

F-10

IDEALARC® DC-600

S22

980

ELECTRODE CABLE

-

+

14 PIN

AMPHENOL

POWER SOURCE

TO WORK

AND 14-PIN CABLE PLUG, REAR VIEW

AND 14-PIN CABLE PLUG, FRONT VIEW

K=42

I=41

H=21

D=4

C=2

PIN

B

C

D

E

F

75

76

77

4

2

LEAD

42V AC

42V AC

TRIGGER CIRCUIT

(SEE APPROPRIATE WIRING DIAGRAM)

FUNCTION

FUNCTIONS ARE LISTED FOR REFERENCE

ONLY AND EACH MAY OR MAY NOT BE

PRESENT IN YOUR EQUIPMENT.

14-SOCKET BOX RECEPTACLE, FRONT VIEW

14-SOCKET BOX RECEPTACLE, REAR VIEW

N.C. PINS NOT LISTED ARE NOT CONNECTED

ON CABLE.

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT

AND DUTY CYCLE OF APPLICATION.

G

21

H

41

I

42

J

M

F=76

E=77

G=75

N

L

A

B=GND

K=42

I=41

H=21

D=4

C=2

J

M

F=76

E=77

G=75

N

L

A

B=GND

9 PIN

AMPHENOL

K

GND

CHASSIS CONNECTION

WORK

OUTPUT CONTROL

OUTPUT CONTROL

OUTPUT CONTROL

TRIGGER CIRCUIT

Only qualified persons should install, use or

service this machine.

Do not operate with covers removed.

Disconnect power source before

servicing.

Do not touch electrically live parts.

N.D. IF LEAD #21 IS TO BE CONNECTED TO THE

TERMINAL STRIP, CONNECT TO THE #21

TERMINAL THAT MATCHES WORK POLARITY.

THIS CONNECTION MUST BE CHANGED WHENEVER

THE ELECTRODE POLARITY IS CHANGED.

10-30-98F

N.E.

N.E. ILLUSTRATION DOES NOT NECESSARILY REPRESENT

ACTUAL POSITION OF APPROPRIATE OUTPUT STUDS.

MORE INFORMATION.

CONNECTION OF DH-10 OR LN-10 TO POWER SOURCE WITH 14 PIN AMPHENOL

REFER TO POWER SOURCE OPERATING MANUAL FOR

LINCOLN

WIRE

FEEDER

WIRE FEEDER

INPUT CABLE

ASSEMBLY

N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO

CHANGE POLARITY, TURN POWER "OFF",

REVERSE ELECTRODE AND WORK CABLES AT

POWER SOURCE.

FOR PROPER SETTINGS OF SWITCHES ON POWER SOURCE,

SEE POWER SOURCE OPERATING MANUAL.

Advertising