Diagrams, Idealarc® dc-600 – Lincoln Electric IM642 IDEALARC DC-600 User Manual

Page 47

Advertising
background image

F-6

DIAGRAMS

F-6

IDEALARC® DC-600

N.C. Tape up bolted connection if lead #21 is extended.

N.D. Connect the control cable ground lead to the frame terminal

marked near the power source terminal strip. The power

source grounding terminal (marked and located near the power

source input power connections) must be properly connected to

electrical ground per the power source operating manual.

N.E. If an optional remote voltage control is used, connect it to

this terminal strip.

N.A. Welding cables must be of proper capacity for the current and

duty cycle of immediate and future applications. See LN-7

Operating Manual for proper sizes.

N.B. If LN-7 is equipped with a meter kit, extend LN-7 control cable

suitable for the installation. An S16586-[LENGTH] remote

voltage sensing work lead may be ordered for this purpose.

Connect it directly to the work piece independent of the welding

work cable connection. For convenience, this extended #21 lead

should be taped to the welding work lead. (If the length of

welding work cable is short, less than 25 feet, and connections

can be expected to be reliable, then control cable lead #21 does

not need to be extended and can be directly connected to

terminal #21 on the terminal strip. Note that this is not the

preferred connection because it adds error to the LN-7 voltmeter

Above diagram shows electrode connected positive. To change polarity,

turn power off, reverse the electrode and work leads at the power

41

423

1

32

75

76

77

NEGATIVE

POSITIVE

32 31 2 4

GND

21

N.A.

N.D.

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

POWER SOURCE

N.E.

N.F.

reading.)

N.F.

If lead #21 is to be connected to

the terminal strip,

connect to the #21 terminal that matches

work polarity. This

connection must be changed whenever the

electrode polarity is

changed.

Only qualified persons should install, use or

service this machine.

Do not operate with covers removed.

Disconnect power source before

servicing.

Do not touch electrically live parts.

LN-7 TO INPUT

CABLE PLUG

LN-7 CONTROL

CABLE

21

-

21

FOR CONTROL CABLE

WITH 14 PIN

MS-TYPE

PLUG CONNECTOR

OR

FOR CONTROL CABLE

WITH TERMINAL STRIP

LEAD CONNECTORS

CONTROL CABLE

S22

97

6

source and position the switch on wire feeder (if equipped )

to proper polarity. Also refer to note N.F.

N.B. & N.C.

14-PIN

RECEPTACLE

lead #21 from control cable with terminal strip connectors or from

14-pin receptacle using #14 AWG or larger insulated wire physically

21

+

REMOTE VOLTAGE SENSING LEAD

10-30-98F

N.G.

N.G. Illustration does not necessarily represent actual position of

for more information.

CONNECTION OF LN-7 TO THE CV-655, DC-655 OR DC-600 POWER SOURCE

appropriate output studs. Refer to power source operating manual

For proper setting of switches on power source,

see power source operating manual.

Advertising