Installation, Technical specifications – dc655e (ce) – Lincoln Electric IM983 RED-D-ARC DC655e (CE) User Manual

Page 10

Advertising
background image

A-1

DC655e (CE) (RED-D-ARC)

A-1

INSTALLATION

TECHNICAL SPECIFICATIONS – DC655e (CE)

Volts at Rated Amperes

44

44

Auxiliary Power

See the OPERATION section for

Auxiliary Power information

Amps

650

815

Maximum Open Circuit Voltage

46 CV Mode

68 CC Mode

Duty Cycle

100% Duty Cycle

IEC974-1

60% Duty Cycle

INPUT - THREE PHASE ONLY

OUTPUT

1Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.

RECOMMENDED INPUT WIRE AND FUSE SIZES

Standard

Voltage

230/400/50/60*

100% Duty Cycle

122/70

60% Duty Cycle

150/86

Input Current at Rated Output

RATED OUTPUT

INPUT

VOLTAGE /

FREQUENCY

230
400

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

1

225 Amp
125 Amp

Copper

GROUND WIRE

IN CONDUIT

AWG(IEC-MM

2

) SIZES

4 (21)
6 (14)

TYPE 80°C

COPPER WIRE

IN CONDUIT

AWG(IEC-MM

2

) SIZES

40°C (104°F) Ambient

1 (43)
4 (21)

INPUT AMPERE

RATING ON

NAMEPLATE

122

70

HERTZ

50/60
50/60

PHYSICAL DIMENSIONS

HEIGHT

27.5 in

699 mm

WIDTH

22.2 in

564 mm

DEPTH

38.0 in

965 mm

WEIGHT

720 lbs.

326 kg.

Current Range

50-815

Voltage Range

13-44 DC