Installation – Lincoln Electric IM983 RED-D-ARC DC655e (CE) User Manual

Page 15

Advertising
background image

A-6

INSTALLATION

DC655e (CE) (RED-D-ARC)

A-6

6-PIN MS TYPE RECEPTACLE

Refer to figure A.5 for for the available circuits in the
6 -Pin MS type connector.

TERMINAL STRIPS

Terminal strips are available behind the cover panel
on the lower case front to connect wire feeder control
cables that do not have a 6-Pin and a 14-Pin MS-type
connector. Refer to figure A.3 for the location of this
cover panel. These terminals supply the connections
as shown in the following Terminal Strip charts. See
Auxiliary Power Table for rating of circuit breaker in
115VAC circuit. Remove a plug button from the termi-
nal strip cover and install an appropriate strain relief
clamp for the cable being used. NOTE: There are two
work sense lead connection points on the terminal
strip. Connect both the work sense lead #21 from the
14-Pin connector and #21 lead of the control cable to
“-21” when welding positive polarity or to “+21” when
welding negative polarity.

TERMINAL STRIP 1 (T.S.1)

TERMINAL STRIP 2 (T.S.2)

Lead No.

Function

75

Output Control

76

Output Control

77

Output Control

1

If connecting a feeder cable directly to the terminal strip, Lead #21
from the cable is connected to “-21” on the terminal strip for posi-
tive welding. If welding negative polarity, connect lead #21 to the
“+21” connection point on the terminal strip.

Lead No.

Function

+21

Work Connection

-21

Work Connection

1

41

42 VAC

4

Trigger Circuit

2

Trigger Circuit

31

115 VAC

32

115 VAC

FIGURE A.5 FRONT VIEW OF 6-PIN CONNECTOR
RECEPTACLE

PIN

LEAD NO.

FUNCTION

A

77

Output Control

B

76

Output Control

C

75

Output Control

D

2

Trigger Circuit

E

4

Trigger Circuit

F

GND

Chassis Connection

D = 2

E = 4

F = G N D

A = 7 7

B = 7 6

C=75