Troubleshooting, Caution – Lincoln Electric IM983 RED-D-ARC DC655e (CE) User Manual

Page 27

Advertising
background image

E-3

TROUBLESHOOTING

E-3

DC655e (CE) (RED-D-ARC)

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Machine has output, but no control.

Machine does not have maximum
output.

Poor arc striking with semiautomatic
or automatic wire feeders.

1. Check the Local/Remote output

switch (SW3) and associated
leads. See wiring diagram.

2. Make sure the remote control

leads #75, #76 and /or #77 are
NOT grounded to either welding
output.

3. Make sure control cable to feeder

(if used) is connected properly.

4. The output control potentiometer

may be faulty.

5. The control or firing board may

be faulty.

1. Make sure the correct three-

phase input is applied to the
DC655e (CE) machine.

2. The output control potentiometer

may be faulty.

3. The control or firing board may

be faulty.

1. Make sure the mode switch is in

the proper position for the
process.

2. Make sure the welding cables

and connections are secure.

3. Check for correct welding porce-

dures.

Contact your Local Authorized Field
Service

Facility

for

technical

troubleshooting assistance.