Accessories – Lincoln Electric IM983 RED-D-ARC DC655e (CE) User Manual

Page 23

Advertising
background image

C-1

ACCESSORIES

C-1

The DC655e (CE) can be used to power
any of the following Lincoln Wire feeders:

SEMI-AUTOMATIC WIRE FEEDERS

LN-15

DH-10

LN-9*

LN-10

LN-9 GMA*

LN-7 GMA*

LN-23P

LN-742

LN-25

LN-7*

LN-8*

AUTOMATIC WIRE FEEDERS*

NA-3

NA-5R

NA-5

LT-7 Tractor

* 115VAC for these feeders provided at the terminal strip (TS2)

FIELD INSTALLED OPTIONS

K1482-1 Digital Ammeter/Voltmeter Kit - Installs
easily to the front control panel and provides digital
display of actual welding voltage and amperage while
welding. (Installation instructions are included with the
kit).

K1483-1 Analog Ammeter/Voltmeter Kit - Installs
easily to the front control panel and provides analog
display of actual welding voltage and amperage while
welding. (Installation instructions are included with the
kit).

K1485-1 Cable Hanger Bracket - Mounts over stan-
dard lift bale of the DC655e (CE) and provides a cable
hanger on both sides of the power source, each side
capable of holding up to 100 ft. of weld cable.
(Installation instructions are included with the kit).

K1486-1 Air Filter Kit - Removable metal filter easily
slides in and out of a bracket which mounts to the
front of the DC655e (CE). Filter is designed to trap
80% of entering particles which are 5 microns, or larg-
er, in size. (Installation instructions are included with
the kit). Cannot be used with K1528-1 Dual process
switch.

NOTE: A dirty air filter may cause the thermal protec-
tion of the DC655e (CE) to prematurely activate.
Remove and blow out, or wash and dry, the filter
every two months, or less if in extremely dirty condi-
tions. Replace if necessary.

Undercarriage (K817P, K842) - The DC655e (CE) is
designed for use with the Lincoln K817P or K842
Undercarriage. Complete installation instructions are
included with each undercarriage. When any of the
undercarriages are installed, the DC655e (CE) lift bail
is no longer functional. Do not attempt to lift the
machine with the undercarriage attached. The under-
carriage is designed for moving the machine by hand
only. Mechanized towing can lead to injury and /or
damage to the DC655e (CE).

REMOTE OUTPUT CONTROL
(K775 or K857)

An optional “remote output control” is available. This is
the same remote control that is used on other Lincoln
power sources (K775). The K775 consists of a control
box with 28 ft (8.5m) of four conductor cable. This con-
nects to terminals 75, 76, and 77 on the terminal strip
and the case grounding screw so marked with the sym-
bol on the machine. These terminals are located
behind the cover panel on the lower connection panel of
the DC655e (CE). This control will give the same control
as the output control on the machine.

The K857 has a 6-pin MS-style connector which con-
nects to the 6-pin connector on the DC655e (CE).

K1528-1 Dual Process Switch - (Cannot be used
with K1486-1 Air Filter Kit) The Dual-Process Switch
mounts easily to the front of the machine and is
designed to provide a selection between left and right
side output terminals. Each pair of output terminals
can be switched to either the DC655e (CE), high or
low inductance terminals as desired. Wire feed unit
cables and air carbon arc cables can be connected to
either or both sides of the box and with proper con-
nection can provide polarity change with just a switch
change. Selecting one side only energizes those out-
put studs and opens the other side. Installation
instructions are included with the switch.)

K1611-1 Paralleling Kit - Provides interconnection of
two DC655e (CE) machines in parallel for doubling
the current capacity of one machine. This “master”
and “slave” conection configuration allows the “mas-
ter” to control the balanced output of both machines.
Individual protection circuits of both machines function
normally. (Installation instructions are included with
the switch.)

DC655e (CE) (RED-D-ARC)