Installation, Output connections, Electrode and work cables – Lincoln Electric IM983 RED-D-ARC DC655e (CE) User Manual

Page 13

Advertising
background image

A-4

INSTALLATION

DC655e (CE) (RED-D-ARC)

A-4

OUTPUT CONNECTIONS

ELECTRODE AND WORK CABLES

Use the shortest possible cable lengths. See Table
A.1 for recommended cable sizes based on length.

The output terminals are located at the lower front of
the welder behind a hinged door Refer to figure A.3.
Route the welding cables through the slotted strain
reliefs of the base to the welding terminals.

LOW INDUCTANCE TERMINAL
On the DC655e (CE), the inside right Negative (-) out-
put terminal is lower choke inductance. This terminal
is presently only recommended for CV mode welding
with NR203Ni 1% negative polarity procedures. All
other processes are to be welded using the outside
right Negative (-) output terminal with higher choke
inductance. CC mode processes must use high
inductance.

For Positive Polarity:

1. Connect the work cable to the high inductance (-)

terminal (marked " ").

2. Connect the electrode cable to the positive terminal

marked “+”.

3. Remove the terminal strip access cover panel on

the lower case front. Refer to figure A.3 for the
location.

4. Work Sense lead #21 from the 14 Pin MS-recepta-

cle must be connected to “-21”on the terminal strip.
Note: This is how the DC655e (CE) is shipped
from the factory.

5. Replace the terminal strip access cover panel.

For Negative Polarity:

1. Connect the electrode cable to the appropriate high

inductance (-) terminal (marked " ") or
to

the

low

inductance

(-)

terminal

(marked " ") if using NR203Ni 1% elec-
trode only.

2. Connect the work cable to the positive terminal

marked “+”.

3. Remove the terminal strip access cover panel on

the lower case front. Refer to figure A.3 for the
location.

4. Work Sense lead #21 from the 14 Pin MS-recepta-

cle must be connected to “+21”on the terminal strip.

5. Replace the terminal strip access cover panel.

TABLE A.1

Cable Sizes for Combined Lengths of Copper

Electrode and Work Cable

Cable Length

ft. (m)

Parallel Cables

Cable Size

0 (0) to 100 (30.4)

100 (30.4) to 200 (60.8)
200 (60.8) to 250 (76.2)

2
2
2

2/0 ( 70mm

2

)

3/0 ( 95mm

2

)

4/0 (120mm

2

)

POSITIVE
OUTPUT
TERMINAL

LOW INDUCTANCE
NEGATIVE OUTPUT
TERMINAL

HIGH INDUCTANCE
NEGATIVE OUTPUT
TERMINAL

TERMINAL STRIP
COVER PANEL

14 PIN MS RECEPTACLE

6 PIN MS RECEPTACLE

FIGURE A.3 Output Connections