Troubleshooting, Caution – Lincoln Electric IM983 RED-D-ARC DC655e (CE) User Manual

Page 26

Advertising
background image

E-2

TROUBLESHOOTING

E-2

DC655e (CE) (RED-D-ARC)

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Input contactor (CR1) chatters.

Machine input contactor does not
operate.

Machine input contactor operates,
but no output when trying to weld.

1. Faulty input contactor (CR1).

2. Low line voltage.

If Power Pilot light is off:
1. Make sure the proper three-

phase input power is applied to
the DC655e (CE) machine.

2. The power switch (SW1) may be

faulty.

3. The pilot transformer may be

faulty.

If Power Pilot light is on:
1. The input contactor may be

faulty.

2. Input shutdown may be activated

(LED3 on on Control Board). See
Shorted Rectifier Fault
Protection
in Operation Section.

1. Electrode or work cables may be

loose or broken.

2. Firing P.C. board is not connected

or is faulty. See PC board LED
information.

3. Trigger circuit may not be working.

Place Output Terminals Switch to
the ON position, or place a jumper
wire across #2 and #4 on the ter-
minal strip. If output is enabled
then check control cable to feeder
if connected.

4. If the thermal protection light is

ON the machine is overheated.
Make sure the fan is operating
and remove the cause of the
overheating problem.

Contact your Local Authorized Field
Service

Facility

for

technical

troubleshooting assistance.