Troubleshooting, Caution – Lincoln Electric IM983 RED-D-ARC DC655e (CE) User Manual

Page 28

Advertising
background image

E-4

TROUBLESHOOTING

E-4

DC655e (CE) (RED-D-ARC)

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Variable or sluggish welding arc.

Output Control Pot not functioning in
“Local” control only.

No output control in “Remote” control
only.

1. Make sure the mode switch is in

the proper position for the
process.

2. Make sure the welding cables are

sized correctly and the connec-
tions are tight.

3. Make sure the welding proce-

dures are correct.

1. Check the Local/Remote control

switch and associated leads.
See wiring diagram.

2. The machine output control

potentiometer may be faulty.
Also check associated leads.
See wiring diagram.

1. Output Control Switch in wrong

position.

2. Faulty Output Control Switch.

3. Faulty Remote Control Pot.

4. Leads or connections open in con-

trol circuit. (#75, #76, #77)

Contact your Local Authorized Field
Service

Facility

for

technical

troubleshooting assistance.

Advertising