Star Water Systems S1101 User Manual
Page 14
Advertising
![background image](/manuals/365188/14/background.png)
14
Do not drill in
Cross-hatched areas
of tank
3 in. hole
2 in.
Pipe Seal
5 in. Min.
1-1/2 in. Min.
7 in. Min.
7 in. Min.
2 in. Min.
6 in. Min.
Do not drill in
Cross-hatched areas
of tank
INSTALLATION OF ADDITIONAL FIXTURES
3
4
3. Insert 2 in. pipe seal (included) into the 3 in. hole drilled
in Step 2. Lubricate the inside diameter of the seal with
soapy water to make it easier to insert pipe.
NOTE: Pipe installed in this 2” seal must be supported
vertically.
4. Insert approximately 3/4 in. of pipe through seal into
the tank.
NOTE: The bottom of the 3 in. hole drilled in Step 2
must be a minimum of 5 or 6 in. above the base of the
tank, depending on where the hole is drilled.
See Figures 5, 6, 7 and 8 for typical installations.