Van Air Systems Dew Point Meter 46-2529 2-02 User Manual

Page 4

Advertising
background image

2

INTRODUCTION


The 6392N is a Digital Dew Point Monitor PC Board with relay setpoint, digital display and linear
transmitter. This product is ideal for OEM applications on desiccant dryers. A complete monitoring
system includes the 6392N (or 6392N2), a 1205DM Hygrosensor, and a variety of supporting
accessories.

SPECIFICATIONS

Dew Point Range

-40

F to +15 F (-40 C to -9 C)


Sensor Part #

1205DM


Accuracy

+2

F


Alarm Set Point

-10

F (-23 C) (Adjustable, see Calibration Section.)


Remote Alarm Output

Normally open and normally closed contacts, 5A @ 115V rated


Recorder Output

4-20 mA and 0-5V

NOTE:

Use one (1) of the following equations when determining

the corresponding dewpoint for milliamp (mA) or voltage (V) outputs.

MA = DP + 67.5 or V = DP + 40
6.875 22

(-40 = 4 mA or 0 V; 70 = 20 mA or 5 V)


Power Requirements

115 VAC +10% (230 VAC Available) 50/60Hz

Or 18VDC to 28VDC (-24V versions)


Power Consumption

4 Watts max


Dimensions

3.5"W

x

5.75"H

INSTALLATION

1.

The 6392N is designed to be mounted behind a panel with the built-in display showing through.


2.

Drill and punch holes in your panel as shown on 6392N Mounting Drawing.

NOTE:

If Newport Scientific bezel # 1835002 is used, the two (2) top mounting holes
aren't required.


Advertising