x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide

59

Running QoS within a VCS stack

In general you can apply the same principles when configuring QoS on a
VCS stack as you would for single switch; however there are a few specific
changes that you will need to make. See the AlliedWare Plus Software
Reference
more information on this topic.

Stack Member

Failure and

Recovery

Management IP Addresses

A single virtual MAC address, from the current Master, is used as the stack
MAC address. If the stack master fails, the stack MAC address changes to
reflect the new master's MAC address. If the stack MAC address does
change, ARP tables of devices on the network are updated to reflect the
change in MAC address via gratuitous ARP.

1- L/A

Solid
Green

Link on stacking port 1 is active.

Green
Flashing

Indicates traffic flowing through stacking port 1

Green OFF Link on stacking port 1 is inactive.

2- L/A

Solid
Green

Link on stacking port 2 is active.

Green
Flashing

Indicates traffic flowing through stacking port 2.

OFF

Link on stacking port 2 is inactive.

PRES

Solid
Green

VCS Stacking Module (AT-StackXG) or
Loopback Module (AT-LBM) has been
inserted, i.e. is PRESENT.

STATUS LEDs

MASTER

Solid
Green

The switch is the Stack Master.

Green
Flashing

When the STACK INDICATOR command is
activated, this LED will flash with a pattern that
indicates the stack member ID of the switch.

LED State

Description

(Continued)