GW Instek PSW-Series User Manual User Manual
Page 164

PSW Series User Manual
164
CV/CC/ALM/PWR ON/OUT
ON indicator
Photocoupler open collector output;
Maximum voltage 30V, maximum sink
current 8mA.
Front Panel
Display, 4 digits
Voltage accuracy
0.1% +
mV 20
20
100
200
400
Current accuracy
0.1% +
mA 40
20
5
5
2
Indications
GREEN LED's: CV, CC, VSR, ISR, DLY, RMT,
20, 40, 60, 80, 100, %W, W, V, A
RED LED's: ALM
Buttons
Function, OVP/OCP, Set, Test, Lock/Local,
PWR DSPL, Output
Knobs
Voltage, Current
USB port
Type A USB connector
Programming and Measurement (USB, LAN, GPIB)
Output voltage programm-
ing accuracy 0.1% +
mV 10
10
100
200
400
Output current programm-
ing accuracy 0.1% +
mA 30
10
5
5
2
Output voltage
programming resolution
mV 1
2
3
5
14
Output current
programming resolution
mA 1
1
1
1
1
Output voltage measure-
ment accuracy 0.1% +
mV 10
10
100
200
400
Output current measure-
ment accuracy 0.1% +
mA 30
10
5
5
2
Output voltage
measurement resolution
mV 1
2
3
5
14
Output current
measurement resolution
mA 1
1
1
1
1
Series and Parallel Capability
Parallel number
Units
3
3
3
3
3
Series Number
Units
2
2
2
None None