Master-Slave Parallel Connection
Master-Slave
Connector
The Analog Control Connector is used for both
serial and parallel connections. The way the
connector is configured determines the
behavior of the master and slave units. For the
complete connector pin assignment, see page
117.
Analog Connector
Connection
To operate the power supplies in parallel,
connect the analog connectors on the master
and slave units as shown in the diagrams
below.
Alternatively pre-configured cables (optional)
can be used. The PSW-006 is used for two units
in parallel. The PSW-007 is used for 3 units in
parallel.
Master with 2 slave units: