84
Analog Connector
Connection
To operate the power supplies in series, connect
the analog connectors on the master and slave
unit as shown in the diagram below.
Alternatively, the optional PSW-005 cable is
pre-configured for serial use.
2
12
17
20
21
Master unit
A COM
16
OUTPUT ON STATUS
21
ALM STATUS
20
STATUS COM
17
SHUTDOWN
12
Slave Unit 1
25
SER SLV IN
20
ALM STATUS
12
SHUTDOWN
2
D COM
24
OUT OFF/ON CONT
2
D COM
24 20
12
17
25
2
16
17
STATUS COM
Series Output
Connection
Master unit
Load
+
-
Slave unit
Steps
1. Ensure the power is off on both power supplies.
2. Choose a master and slave unit.
3. Connect the analog connectors for the master
and slave unit as shown above.
4. Remove the output terminal cover
and the protection dummy plug
from the analog control connector.