Remove test script – GW Instek PSW-Series User Manual User Manual

Page 94

Advertising
background image

PSW Series User Manual

94

Note

If the USB drive is not recognized, check to see
that the function settings for F-20 = 1 (page 106). If
not, reinsert the USB flash drive.

3. Configure T-03 (Test Export) to

0~10 (save memory slot)

Page 89

T-03 range

1~10

4. The script will now be copied to the USB flash

drive.

Note

Error messages: If you try to export a test script
from an empty memory location “Err 003” will be
displayed on the display.

Remove Test Script

Overview

The Remove Test function will delete a test
script from the internal memory.

Steps

1. Select T-04 (Test Remove) and

choose which test script to remove
from the internal memory.

Page 89

T-04 range

1~10

2. The test script will be removed from the

internal memory.