[:CONFigure]:VON

Set

Query

Description

Sets or queries the Von voltage settings.

Syntax

[:CONFigure]:VON {<NRf>[ V ] | MINimum|
MAXimum | LON | LOFF }

Query Syntax

[:CONFigure]:VON?

Parameter

{<NRf>[ V ]

The Von voltage level
(default unit is V)

MINIMUM or MIN

Minimum Von voltage
level

MAXIMUM or MAX

Maximum Von voltage
level

LON

Latch on

LOFF

Latch off

Return parameter <ASCII string>

Returns the Von latch
settings.

Example

:VON 10.0V
Sets the Von voltage to 10.0 volts.

Query example

:VON?
>Latch OFF, 10.000
The Von voltage level is 10V.

[:CONFigure]:VDELay

Set

Query

Description

Sets or queries the Von Delay settings in seconds.

Syntax

[:CONFigure]:VDELay {<NRf>[s] | MINimum |
MAXimum | OFF }

Query Syntax

[:CONFigure]:VDELay?

Parameter

<NRf>[s]

The delay time in seconds

OFF

Disable the delay time

MINIMUM or MIN

Minimum delay time

MAXIMUM or MAX

Maximum delay time

Return parameter <NR2>

Returns the delay time in
seconds