GDS-806/810/820/840 Programming Manual

65

:TRIGger:PULSe:TIMe

Select the time value for pulse width. The setting range is from 20ns to 10s.

Syntax

:TRIGger:PULSe:TIMe <NR3>

:TRIGger:PULSe:TIMe?

Arguments

<NR3>

is the desired time value of pulse width, the unit is in second.

Returns

<NR3>

:TRIGger:REJect

Select and query the frequency rejection mode.

Syntax

:TRIGger:REJect <0|1|2>

:TRIGger:REJect?

Arguments

0

→OFF

1

→Low frequency reject mode

2

→High frequency reject mode

Returns

<NR1>