Chapter 4 buoy transceiver, 1 overview, 2 addressing – In-Situ Aquaculture Buoy Manual (purchased before 28 May 2013) User Manual

Page 13: 1 changing buoy addresses, Chapter 4, Buoy, 1 overview 4.2 addressing

Advertising
background image

Buoy Transceiver

13

Chapter 4

Buoy Transceiver

4.1

OVERVIEW

The transceiver consists of:

• A microprocessor that is programmed to take sensor readings at

given intervals

• A radio module that transmits the sensor readings to the host PC
• A desiccant pack (PN 0063100)

In between the readings, the radio module operates in sleep mode,
enabling the buoy to operate with lower power consumption.

4.2

ADDRESSING

Each transceiver has a different address that identifies the buoy when
communicating with the host PC.

If your transceiver arrives with a large number on the outside of the
box, your buoy has already been addressed with the number on the
transceiver. You will not need to change anything. If a buoy does not
arrive pre-addressed or is moved to a different pond, the address will
need to be updated.

4.2.1

Changing Buoy Addresses

Note: If you change the
buoy address after
powering the system, you
will need to disconnect and
reconnect power for the
address change to take
effect.

A switch module on the transceiver board sets the buoy address. The
switch has the following characteristics:

• It is a binary switch
• The address is the sum of the values of the binary switches that are

in the “on” position

To access the switch, use a screwdriver to remove the transceiver box