C. Advanced setup

B.2.3

Device ID

This displays device order no, V-no,

service no, Ex approval, Main CPU

version, Companion CPU version and

DSP version.

Read only

B.2.4

Quick Setup

Sum.

A summary of the parameters entered

in the quick setup menu

Read only

B.2.5

TAG number

The TAG number can be seen and

updated here

?

TAGNO0123

4567890

Temperature

Temperature of the electronics block.

The display will automatically switch

off if the temperature is below -20°C /

-4°F or above +60°C / +140°F.

Read only

B.2.6

Error Records

A log of device errors. Scroll down the

list and push [^

^

^

^] to display the error

details. Opening a log will remove the

error icon if it appeared in operator

mode.

Read only

Measurement

Quality

Status of device errors at this time. A

"tick" symbol next to an error in the list

shows that this error is active and may

have an unwanted effect on the device.

Read only

B.2.7

Custom.

Length Unit

Non-standard length unit for the

conversion table. This is defined by the

supervisor. Go to Supervisor >

Supervisor >

Supervisor >

Supervisor >

Advanced Setup > Device Setup >

Advanced Setup > Device Setup >

Advanced Setup > Device Setup >

Advanced Setup > Device Setup >

Display Settings > Custom. Length Unit

Display Settings > Custom. Length Unit

Display Settings > Custom. Length Unit

Display Settings > Custom. Length Unit

or follow the procedure in the

Conversion

Conversion

Conversion

Conversion setup menu.

Read only

B.2.9

Custom. Conv.

Unit

Non-standard conversion unit for the

conversion table. This is defined by the

supervisor. Go to Supervisor >

Supervisor >

Supervisor >

Supervisor >

Advanced Setup > Device Setup >

Advanced Setup > Device Setup >

Advanced Setup > Device Setup >

Advanced Setup > Device Setup >

Display Settings > Custom. Conv. Unit

Display Settings > Custom. Conv. Unit

Display Settings > Custom. Conv. Unit

Display Settings > Custom. Conv. Unit

or follow the procedure in the

Conversion

Conversion

Conversion

Conversion setup menu.

Read only

Menu

No.

Function

Function description

Selection list

Default

C.1 Installation Setup

C.1.1

Installation

Type

The installation on the silo for the

device.

Metal / concrete silo, Plastic

silo, Free Air Application

Metal /

concrete silo

C.1.2

Tank Height /

Measuring

Range

"Tank height" is the distance from the

silo connecting flange face/thread stop

to the silo bottom. "Measuring range"

(for "Free Air Application" only) is the

maximum distance that the device

must measure.

min-max:

0.20…80 m / 0.66…262 ft

20 m / 65.61 ft

C.1.3

Application

Type

The conditions in which the device is

used. If the surface of the product is

flat, select "Flat surface". If there is a

slightly uneven surface, select

"Medium slope". If the surface has a

steep slope, select "Steep slope".

Flat surface, Medium slope,

Steep slope

Medium slope

C.1.4

Stillwell Height

Not available. For liquid applications

only.

n/a

n/a

Menu
No.

Function

Function description

Selection list

Default