ELECTRICAL CONNECTIONS

4

43

MFC 400

www.krohne.com

08/2013 - 4002075802 - MA MFC 400 R02 en

4.10.4 Modular inputs/outputs and bus systems

Current output active (only current output terminals C/C- have HART

®

capability),

modular I/Os

• U

int, nom

= 24 VDC

• I ≤ 22 mA
• R

L

≤ 1 kΩ

• X designates the connection terminals A, B or C, depending on the version of the signal

converter.

Current output passive (only current output terminals C/C- have HART

®

capability),

modular I/Os

• U

ext

≤ 32 VDC

• I ≤ 22 mA
• U

0

≥ 1.8 V

• R

L

≤ (U

ext

- U

0

) / I

max

• X designates the connection terminals A, B or C, depending on the version of the signal

converter.

CAUTION!
Observe connection polarity.

INFORMATION!
•

For further information on electrical connection refer to Description of the inputs and outputs
on page 38.

•

For the electrical connection of bus systems, please refer to the separate documentation for
the respective bus systems.

Figure 4-11: Current output active I

a

Figure 4-12: Current output passive I

p

.book Page 43 Monday, August 26, 2013 9:05 AM