Example program, English – West Control Solutions 9500 User Manual

Page 13

Advertising
background image

13

TYPE

SPR

SPRR

105

T.SP

137

TYPE

SOAK

SINT

45

TYPE

STEP

T.SP

85

TYPE

SPR

SPRR

55

T.SP

30

TYPE

LOOP

PCYC

1

TYPE

SPR

SPRR

105

T.SP

137

TYPE

SOAK

SINT

45

TYPE

STEP

T.SP

85

TYPE

SPR

SEG

1

SEG

2

SEG

3

SEG

4

SEG

5

PROG

3

SEG

1

SEG

2

SEG

3

SEG

4

STOP

30

SPRR

55

T.SP

30

EXAMPLE PROGRAM

Temp

Time

See segment configuration of this
program detailed on page 18.

Ramp Function

Rate, 105 deg/hour
Target setpoint: 137 deg

Ramp Function

Rate, 55 deg/hour
Target setpoint: 30 deg

Loop Function

Number of repeat
program cycles: 1

Step Function

Target setpoint: 85 deg

Soak Function

Interval: 45 mins

English

Advertising