Ecochill chiller – Airedale EcoChill 6kW - 46kW User Manual

Page 16

Advertising
background image

16

EcoChill

Chiller

Technical Manual 7300221 V1.1.0_02/2013

COOLING

020H 025H 030H 040H 050H 070H 080H 090H 100H 150H 200H

Cooling capacity

kW

5.7

6.2

7.5

9.6

13.4

16.5

20.5

22.3

26.0

32.0

42.0

Total input power

(°)

kW

1.84

2.00

2.46

3.25

4.03

4.88

6.33

6.63

8.6

10.2

13.9

A/P

kW

1.99

2.15

2.61

3.40

4.30

5.15

6.60

6.90

9.2

11.2

14.9

Q/N

kW

-

-

-

-

4.48

5.33

6.78

7.08

9.6

11.5

15.2

Evaporator water flow rate

l/h

980

1070

1290

1650

2310

2840

3530

3840

4470

5500

7220

Evaporator pressure drops

kPa

29.0

30.0

30.0

27.0

30.0

30.0

36.0

50.0

41.0 37.0 31.0

HEATING

Heating capacity

kW

6.2

7.0

8.4

10.6

14.0

17.3

22.2

24.2

29.0

35

46

Total input power

(°)

kW

1.91

2.12

2.62

3.18

4.30

4.90

6.30

6.85

8.6

10.1

13.3

A/P

kW

2.06

2.27

2.77

3.33

4.57

5.17

6.57

7.12

9.2

11.1

14.3

Q/N

kW

-

-

-

-

4.75

5.35

6.75

7.30

9.6

11.4

14.6

Evaporator water flow rate

l/h

1070

1200

1450

1820

2410

2980

3820

4160

4990

6020

7910

Evaporator pressure drops

kPa

32.0

35.0

35.0

30.0

30.0

30.0

38.0

53.0

52.0 44.0 37.0

ENERGY EFFICIENCIES

EER

W/W

3.10

3.10

3.05

2.95

3.33

3.38

3.24

3.36

3.03

3.14

3.02

COP

W/W

3.25

3.30

3.21

3.33

3.26

3.53

3.52

3.53

3.39

3.47

3.46

ESEER

3.72

3.72

3.66

3.54

3.99

4.06

3.88

4.03

3.98

4.11

3.95

ELECTRICAL DATA

Total input current in COOLING mode

(version without circulation pump)

(°)

400V

A

3.7

4.2

4.70

6.2

8.7

9.7

12.2

12.8

17.0

19.2

26.2

230V

9.4

10.0

13.0

16.3

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

Total input current in COOLING mode

(version with circulation pump)

A/P

400V

A

4.7

5.2

5.70

7.2

10.7

11.7

14.2

14.8

18.2

21.2

28.2

230V

9.4

10.0

13.0

16.3

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

Q/N

400V

N.A.

N.A.

N.A.

N.A.

11.4

12.4

14.9

15.5

19

21.8

28.8

Total input current in HEATING mode

(version without circulation pump)

(°)

400V

A

3.8

4.4

5.4

6.8

9.5

10.3

12.9

13.8

17.0

19.0

25.0

230V

10.4

11.0

14.0

17.3

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

Total input current in HEATING mode

(version with circulation pump)

A/P

400V

A

4.8

5.4

6.4

7.8

11.5

12.3

14.9

15.8

18.2

21.0

27.0

230V

10.4

12.3

14.0

19.3

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

Q/N

400V

N.A.

N.A.

N.A.

N.A.

12.2

13.0

15.6

16.5

19.0

21.6

27.6

Maximum current (FLA)

(version without circulation pump)

(°)

400V

A

6

6

6.7

8.7

11.3

13.5

16.3

17.3

22.0

26.0

34.0

230V

16.5

16.5

19.7

23.7

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

Maximum current (FLA)

(version with circulation pump)

A/P

400V

A

7

7

7.7

9.7

13.3

15.5

18.3

19.3

23.4

28.8

36.8

230V

17.5

17.5

20.7

24.7

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

Q/N

400V

N.A.

N.A.

N.A.

N.A.

14.0

16.2

19.0

20.0

23.4

28.8

36.8

Peak current (LRA)

(version without circulation pump)

(°)

400V

A

26.5

32.5

35.70

48.7

65.3

75.3

102.3

96.3

76.0

87.0

117.0

230V

59.5

62.5

83.70

98.7

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

Peak current (LRA)

(version with circulation pump)

A/P

400V

A

27.5

33.5

36.70

49.7

67.3

77.3

104.3

98.3

77.4

89.8

119.8

230V

60.5

63.5

84.7

99.7

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

N.A.

Q/N

400V

N.A.

N.A.

N.A.

N.A.

68.0

78.0

105.0

99.0

78.8

90.5

120.5

COMPRESSORS (SCROLL)

Number/circuit

1/1

1/1

1/1

1/1

1/1

1/1

1/1

1/1

2/1

2/1

2/1

Compressors sump resistance

n°xW

1x70

1x70

1x70

1x70

1x35

1x35

1x35

1x65 2X35 2X35 2X65

Capacity controls

%

0-100

0-100

0-100

0-100

0-100

0-100

0-100

0-100 0-50-100 0-50-100 0-50-100

FANS (AXIAL)

Number

1

1

1

1

2

2

2

2

2

2

2

Air flow rate

mc/h

2500

2500

3500

3500

7200

7200

7300

7200 13200 12000 12000

Input power

kW

0.085 0.085

0.14

0.14

0.28

0.28

0.28

0.28

0.6

0.6

0.6

Input current

A

0.45

0.45

0.66

0.66

1.32

1.32

1.32

1.32

2.6

2.6

2.6

EVAPORATORS (HEAT PLATE)

Number

1

1

1

1

1

1

1

1

1

1

1

REFRIGERANT CHARGE
R410A

H/HP

Kg

1.500 1.500 1.800 2.060 4.150 4.100 4.140 5.080

12.7

17.0

17.0

HA

1.500 1.500 1.800 2.060 4.150 4.150 4.140 5.080

12.7

17.0

17.0

CIRCULATION PUMP

Input power

kW

0.15

0.15

0.15

0.15

0.27

0.27

0.27

0.27

0.6

1.0

1.0

Input current

A

1.04

1.04

1.04

1.04

1.95

1.95

1.95

1.95

1.2

2.0

2.0

Avaliable pump head

kPa

60.0

60.0

59.0

55.0

82.0

80.0

69.0

66.0

84.0

115.0

90.0

LARGER CIRCULATION PUMP

Input power

kW

N,D,

N,D,

N,D,

N,D,

0.45

0.45

0.45

0.45

1

1.3

1.3

Input current

A

N,D,

N,D,

N,D,

N,D,

2.7

2.7

2.7

2.7

2

2.6

2.6

Avaliable pump head

kPa

N,D,

N,D,

N,D,

N,D,

160

158

144

140

STORAGE TANK

Water storage

l

25

25

35

35

75

75

75

75

100

100

100

HYDRAULIC CONNECTIONS

Inlet for water circulation

Ø

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

Outlet for water circulation

Ø

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

1"¼

NOISE DATA

Sound power

dB(A)

61.0

61.0

68.0

68.0

69.0

69.0

69.0

68.0

76.0

77.0

78.0

Sound Pressure

dB(A)

30.0

30.0

37.0

37.0

38.0

38.0

38.0

37.0

44.0

45.0

46.0

IN COOLING MODE

- Water inlet temperature

12 °C

- Water outlet temperature

7 °C

- External air temperature

35 °C

- ∆t

5°C

IN HEATING MODE

- Water inket temperature

40 °C

- Water outlet temperature

45 °C

- External air temperature

b.s. 7 °C/b.u. 6 °C

- ∆t

5°C

Sound power

Airedale determines sound power values in agree-

ment with the 9614 Standard, in compliance with that

requested by Eurovent certification.

Sound Pressure

Sound pressure measured in free field conditions

with reflective surface (directivity factor Q=2) at 10 mt

distance from external surface of unit, in compliance

with ISO 3744 regulations.