Factory shipments, Installation tools, User supplied materials – Badger Meter GALAXY User Manual

Page 7: Endpoint location

Advertising
background image

Installation Manual

Page 7

June 2014

Factory Shipments

The GALAXY endpoint and the encoder can be shipped factory wired with a pre-defined length of lead wire, or the two units

can be shipped separately and connected in the field .
All endpoints are shipped factory programmed to the utility's FCC-assigned frequency .
Endpoints are shipped in a dormant, non-transmitting condition and are activated at installation .

Installation Tools

The following tools are required for field wiring .

NOTE:

N

The tools described here are not needed for factory prewired endpoints .

61658-003

TORX® #T-10 Driver (not shown)

59989-001

Coax Wire Stripper

59991-001

Wire Cutting Pliers

59983-001

Parallel Pliers

Coax Wire Stripper

Wire Cutting Pliers

Parallel Pliers Crimping Tool

Figure 3: Installation tools

User Supplied Materials

Users are required to supply all mounting materials . This includes the hardware and fasteners to mount the endpoints to the

specific surface . The tools needed depend on the type of mounting hardware used .

Endpoint Location

The endpoint must be mounted on a flat surface in suitable indoor, outdoor or submersible environments .
For optimum radio performance, indoors or outdoors, mount the unit as high as possible with minimal surrounding

obstructions and a clear line-of-sight signal path to the gateway receiving antenna .
For optimal radio transmission when mounting in a pit or a vault, make sure to mount the endpoint at or near the center,

when possible .
Keep the endpoint away from large metal objects such as water heaters or furnaces that may block the signal path .