Specifications, 3/4" and 1" meters, Specifications 11 – Badger Meter E-Series Ultrasonic Meters User Manual

Page 11: 3/4" and 1" meters 11

Advertising
background image

SPECIFICATIONS

3/4" and 1" Meters

E-Series Ultrasonic | Residential

Fire Service

Certified under UL 327B Residential Fire

Service Meters – File No 15653,

Control No 4DP3

3/4" (20 mm)

1" (25 mm)

Operating Range

(per UL Listing, at ±1 5% accuracy)

2…30 gpm

2…50 gpm

Operating Range

0 1…32 gpm

0 4…55 gpm

Extended Low-Flow Rate

0 05 gpm

0 25 gpm

Maximum Continuous Operation

32 gpm

55 gpm

Pressure Loss

2 0 psi at 15 gpm

1 8 psi at 25 gpm

Reverse Flow - Maximum Rate

4 0 gpm

9 0 gpm

Operating Performance

In the normal temperature range of 45…85° F (7…29° C), new meter

consumption measurement is accurate to:

• ±1 5% over the normal flow range

• ±3 0% from the extended low flow range to the minimum flow value

Storage Temperature

– 40…140° F (– 40…60° C)

Maximum Ambient Storage

(Storage for One Hour)

150° F (72° C)

Measured-Fluid Temperature Range

34…140° F (1…60° C)

Humidity

0…100% condensing

Maximum Operating Pressure of

Meter Housing

175 psi (12 bar)

Register Type

Straight reading, permanently sealed electronic LCD; digits are

0 28" (7 mm) high

Register Display

• Consumption (up to nine digits)

• Rate of flow

• Alarms

• Unit of measure factory programmed for gallons, cubic feet and cubic meters

Register Capacity

• 10,000,000 gallons

• 1,000,000 cubic feet

• 100,000 cubic meters

Totalization Display Resolution

• Gallons: 0 XX

• Cubic feet: 0 XXX

• Cubic meters: 0 XXXX

Battery

3 6-volt lithium thionyl chloride; battery is fully encapsulated within the register

housing and is not replaceable; 20-year battery life