1/2" and 2" meters, Maintenance, 1/2" and 2" meters 12 – Badger Meter E-Series Ultrasonic Meters User Manual

Page 12: Maintenance 12

Advertising
background image

1-1/2" and 2" Meters

E-Series Ultrasonic | Residential

Fire Service

Certified under UL 327B Residential Fire

Service Meters – File No 15653,

Control No 4DP3

1-1/2" (40 mm)

2" (50 mm)

Operating Range

1 5…100 gpm

2…160 gpm

Extended Low-Flow Rate

0 40 gpm

0 50 gpm

Maximum Continuous Operation

100 gpm

160 gpm

Pressure Loss at Maximum Flow

3 8 psi

4 7 psi

Reverse Flow - Maximum Rate

12 gpm

18 gpm

Operating Performance

In the normal temperature range of 45…85° F (7…29° C), new meter

consumption measurement is accurate to:

• ±1 5% over the normal flow range

• ±3 0% from the extended low flow range to the minimum flow value

Storage Temperature

– 40…140° F (– 40…60° C)

Maximum Ambient Storage

(Storage for One Hour)

150° F (72° C)

Measured-Fluid Temperature Range

34…140° F (1…60° C)

Humidity

0…100% condensing

Maximum Operating Pressure of

Meter Housing

175 psi (12 bar)

Register Type

Straight reading, permanently sealed electronic LCD; digits are

0 28" (7 mm) high

Register Display

• Consumption (up to nine digits)

• Rate of flow

• Alarms

• Unit of measure factory programmed for gallons, cubic feet and cubic meters

Register Capacity

• 100,000,000 gallons

• 10,000,000 cubic feet

• 1,000,000 cubic meters

Totalization Display Resolution

• Gallons: 0 X

• Cubic feet: 0 XX

• Cubic meters: 0 XXX

Battery

3 6-volt lithium thionyl chloride; battery is fully encapsulated within the register

housing and is not replaceable; 20-year battery life

MAINTENANCE

The Badger Meter E-Series Ultrasonic meters are designed and manufactured to provide long-term service with no

maintenance The enclosure, which includes the electronic meter’s ultrasonic sensors, battery and display, is completely

potted, permanently sealed, and non-removable

E-Series® Ultrasonic Meters for Fire Service Applications

www.badgermeter.com

ADE, E-Series, GALAXY, Making Water Visible, ORION, Recordall and RTR are registered trademarks of Badger Meter, Inc Other trademarks appearing in this document are the

property of their respective entities Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system

specifications without notice, except to the extent an outstanding contractual obligation exists © 2014 Badger Meter, Inc All rights reserved

The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503

Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411

Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836

China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412

Legacy Document Number: ESM-IOM-02-EN

Making Water Visible®

Advertising