09-VRX-UM-00408 07/12

OPERATING THE MONITOR

The monitor has two modes of operation, referred to as the RUN mode and the PROGRAM mode. Both the run mode and the
program mode display screen enunciators confi rming the state of the monitor. A quick glance at the lower left hand corner of
the LCD screen will confi rm operating status. Normal operation will be in the run mode. To access the programming mode, press
the MENU key once. The programming indicator will appear signaling that the display is ready to accept programming inputs.
After programming the display with the necessary information, a lock out feature can be turned on to prevent unauthorized
access or changing the meter's setup parameters.

BASIC PROGRAMMING MODE

Keys:

MENU - Switches to PROGRAMMING mode.

Up Arrow - Scrolls forward through the parameters choices and increments
numeric variables.

Right Arrow - Scrolls backward through the parameters choices and moves the
active digit to the right.

ENTER - Used to save programming information, advance to the next programming
parameter, and in the reset process.

Modes:

RUN – Normal operating mode.
PROGRAM – Used to program variables into
the display

Entering Programming Mode – Change to programming
mode by pressing the MENU key once. The mode indicator
will change from RUN to PROGRAM.

Select The ID Unit – At the ID UNIT prompt press the
ENTER key once. The current ID (inside diameter) unit
will begin to fl ash. Using the arrow keys choose INCH for
US measurements or MM for metric measurements. Press
ENTER once to save the meters ID Unit choice and advance
to the pipe ID selection.

Select The Pipe ID – At the ID prompt press the ENTER key once. The current
meter ID (inside diameter) will begin to fl ash. Using the arrow keys enter the
pipe inside diameter. Press ENTER once to save the pipe ID.

NOTE: Specifi cation charts for common types of pipes can be found in the appendix of this manual.

RUN

PROGRAM

RELAY 1

RELAY 2

RUN

and

PROGRAM

Indicators