Select The Display Function – The monitor can display RATE or TOTAL or alternate between BOTH rate and total. At the DISPLAY
prompt press the ENTER key once. The monitor now shows the display mode currently in eff ect. If the current selection is correct,
press the ENTER key to advance to the next parameter. To change to an alternate display mode, use the arrow keys to scroll to
the desired display mode and press ENTER to save the choice.

A TEST function is also available in the Display Function sub-menu. With the test function selected the display acts like a frequency
counter and displays the raw input frequency being supplied to the frequency input terminals. The second line of the test screen
shows transducer signal strength.

Select The Rate Unit – The monitor can display rate in any of
the units listed at the right.

If the current selection is correct, press the ENTER key to
advance to the next parameter. To change to an alternate rate
unit, use the arrow keys to scroll to the desired display units
and press ENTER to save the choice.

Select The Rate Interval – The monitor can display rate

interval in any of the units listed below.

If the current selection is correct, press the ENTER key to
advance to the next parameter. To change to rate interval,
use the arrow keys to scroll to the desired interval and press
ENTER to save the choice.

Select the Totalizer Units - The fl ow totalizer unit is used
to set the fl ow totalizer exponent. This feature is useful for
accommodating a very large accumulated fl ow. The exponent
is a x10

n

multiplier, where “n” can be from -1 (x0.1) to +6

(x1,000,000). Table 4 should be referenced for valid entries
and their infl uence on the display.

If the current selection is correct, press the ENTER key

to

advance to the next parameter. To change to rate interval, use
the arrow keys to scroll to the desired interval and press ENTER
to save the choice.

This completes the basic setup for the meter.

Velocity*

Feet

VEL FEET

Meters

VEL MTRS

Volumetric

Gallons

GALLONS

Liters

LITERS

Millions of Gallons

MGAL

Cubic Feet

CUBIC FT

Million Cubic Feet

M CU FT

Cubic Meters

CUBIC ME

Million Liters

MEGLTRS

Acre Feet

ACRE FT

Oil Barrels (42 GAL)

OIL BARR

Liquid Barrels (31.5 GAL)

LIQ BARR

Mass**

Kilograms

KGS

Pounds

LBS

* - Velocity measurements not available as totalizer units.
** - Mass units require entry of specifi c gravity.

Interval

Displayed as

Seconds

SEC

Minutes

MIN

Hours

HOUR

Days

DAY

Exponent

Display Multiplier

E-1

x 0.1

E0

x 1 (no multiplier)

E1

x 10

E2

x 100

E3

x 1,000

E4

x 10,000

E5

x 100,000

E6

x 1,000,000

TABLE 4 - EXPONENT MULTIPLIERS